Rev. bras. cir. cardiovasc ; 36(2): 268-271, Mar.-Apr. 2021. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1251097

RESUMO

Abstract Inappropriate therapy due to noise oversensing caused a true ventricular fibrillation (VF) and a life-threatening event in a patient. A 19-year-old patient with surgically corrected congenital heart disease and systolic dysfunction had an implantable cardioverter defibrillator implanted for primary prevention in 2013. This patient was admitted at the Emergency Department in June 2018 after receiving eight shocks from the device on the same day, with a prolonged syncope after the third shock. Another noise-induced VF detection occurred, and two inappropriate shocks followed sequentially, causing true VF. Four appropriate shocks were subsequently needed until sinus rhythm was finally restored.


Assuntos
Humanos , Desfibriladores Implantáveis , Arritmias Cardíacas , Cardioversão Elétrica
2.
Rev. bras. cir. cardiovasc ; 23(2): 197-203, abr.-jun. 2008. ilus
Artigo em Inglês, Português | LILACS | ID: lil-492971

RESUMO

OBJETIVO: Descrever a técnica de preparo e a evolução ecocardiográfica das cúspides de homoenxerto decelularizado utilizadas em pacientes com tetralogia de Fallot. MÉTODOS: No período de março de 2005 a agosto de 2007, 15 pacientes foram submetidos ao implante deste tipo de enxerto e foram acompanhados clinicamente e com ecocardiograma para avaliar o resultado morfofuncional dos enxertos. RESULTADOS: O acompanhamento médio foi de 12,7 meses (1-25 meses). A análise ecocardiográfica em médio prazo revelou: insuficiência pulmonar leve em nove (60 por cento) pacientes, moderada em três (20 por cento) e importante em três (20 por cento); a função sistólica do ventrículo direito esteve preservada em 13 (86,7 por cento) pacientes e com disfunção leve em dois (13,3 por cento); 11 (73,4 por cento) pacientes não apresentaram gradientes na via de saída do ventrículo direito (VD), e em quatro (26,6 por cento) pacientes evidenciou-se a presença de estenose leve; a mobilidade da cúspide foi normal em todos os pacientes; não houve espessamento maior de 1,5mm nas cúspides analisadas; não se detectou nenhuma calcificação nas cúspides. Catorze (93,3 por cento) pacientes apresentaram Z score entre -1 e 0,7 e um (6,7 por cento) paciente apresentou anel pulmonar com Z score de + 2,5. CONCLUSÃO: O retalho de homoenxerto decelularizado parece ser uma boa opção para a ampliação da via de saída do VD nos pacientes submetidos à correção total da tetralogia de Fallot em médio prazo.


OBJECTIVE: To describe the technique of implantation and to show the echocardiographic follow-up of the decellularized cusps allografts used in patients with tetralogy of Fallot. METHODS: Fifteen patients underwent this implantation between March 2005 and August 2007 and they were clinically followed-up. An echocardiogram was performed to evaluate the morphofunctional result of the allografts. RESULTS: The mean follow-up was 12.7 months (1-25 months). The echocardiography results showed that pulmonary insufficiency was mild in nine (60 percent) patients, moderate in three (20 percent) patients, and severe in three (20 percent) patients. The results also showed that the systolic right ventricle function was normal in 13 (86.7 percent) and that there was mild dysfunction in two (13.3 percent). Eleven (73.4 percent) patients did not present any gradient in the right ventricular outflow tract and four (26.6 percent) presented mild stenosis. The mobility of the cusps were normal in all cases and there was no thickness larger than 1,5mm. There was no calcification; 14 patients (93,3 percent) presented Z score between -1 and 0,7 and one patient presented dilated pulmonary annulus with a Z score of + 2.5. CONCLUSION: In midium-term follow-up, the decellularized allograft seemed to be a good option for right ventricle outflow tract enlargement in patients underwent tetralogy of Fallot.


Assuntos
Criança , Pré-Escolar , Humanos , Lactente , Implante de Prótese de Valva Cardíaca/métodos , Tetralogia de Fallot/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica , Sistema Livre de Células , Seguimentos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/normas , Insuficiência da Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar , Fatores de Tempo , Resultado do Tratamento , Tetralogia de Fallot/fisiopatologia , Tetralogia de Fallot , Disfunção Ventricular Direita/fisiopatologia , Disfunção Ventricular Direita/cirurgia , Disfunção Ventricular Direita , Obstrução do Fluxo Ventricular Externo/fisiopatologia , Obstrução do Fluxo Ventricular Externo/cirurgia , Obstrução do Fluxo Ventricular Externo , Pressão Ventricular/fisiologia